Chimney Asbestos & Lead Abatement
Licensed, contained asbestos and lead removal — clearance-tested before any other work.
Learn moreCarbon monoxide is the one chimney hazard you can't see, smell, or afford to guess about. We diagnose CO and combustion spillage with instruments — a combustion analyzer reading CO/O2/stack temp, a draft gauge, and a worst-case depressurization test that catches the spillage a calm-day check misses. Because that test looks at how the whole house — exhaust fans, HVAC, tight insulation — pulls on the flue, we're the right crew to both find the source and correct it, whether the fix is a tune, a draft correction, makeup air, or a flue resize. Then we re-measure to verify it; an unverified CO fix is just hope.
A carbon monoxide problem is the one chimney hazard you can't see, smell, or afford to guess about. When a CO detector alarms, when a flame burns wrong, or when a tight home starves an appliance of air, the difference between a real fix and a dangerous reassurance is whether someone measured it. Texas Service Experts diagnoses CO and combustion-spillage problems with instruments — combustion analyzers, draft gauges, and worst-case depressurization testing — and corrects the source, then verifies the fix by re-reading the numbers.
Measurement, not intuition, is what finds the cause — because CO comes from incomplete combustion and from flue gases spilling into the house instead of going up the chimney. We probe the appliance with a combustion analyzer to read CO, O2, and stack temperature, measure draft in inches of water column at the draft hood, and run a worst-case depressurization (BPI-style) test — closing doors and running exhaust fans to put the house at its most negative — to see whether the flue still drafts or spills under real-world conditions. A tight, exhaust-heavy modern home can pull combustion gases back down a chimney that tests fine on a calm day; only worst-case testing catches it.
With the mechanism identified, we correct it at the source. A mis-tuned appliance gets its burner tuned into spec. A flue spilling from a draft problem gets the draft fixed — resizing, a draft-inducer, or a height correction. A house depressurizing the combustion zone gets combustion air added or return leaks sealed. An oversized common flue orphaning a lone water heater after a furnace upgrade gets re-lined to the correct size. The fix matches the actual finding — not a parts-swap guess.
Re-verification is the non-negotiable final step. After the correction, we re-run the combustion and draft readings and re-test under worst-case conditions to confirm CO is in spec and the flue draws without spilling, then document the before-and-after numbers. We address detection, too: standard UL-2034 alarms only sound at 70 ppm and ignore the chronic 5–30 ppm exposure that causes long-term harm, so where appropriate we place low-level (7-ppm) monitors near combustion appliances and sleeping areas, and can wire a spillage interlock that shuts an appliance down on backdraft.
With our crew, a carbon monoxide diagnosis & combustion safety is never guesswork. We scope every job from a graded, photographed inspection first — the NFPA 211 level the evidence calls for — so the work is matched to what your flue and masonry actually need, with the report to prove it. The documented inspection is the record the carbon monoxide diagnosis & combustion safety is built on.
Chimney inspectionA carbon monoxide diagnosis & combustion safety isn't a matter of opinion — it's held to published national standards. Texas Service builds every job to the named codes below and documents it, so the work is provably right for an inspector, an insurer, or a future buyer. These are the universal standards; your city's permit and inspection requirements are confirmed with the local authority before we pull the job.
To confirm spillage, the house goes into worst-case depressurization per BPI combustion-safety practice, doors closed and every exhaust running, and we measure whether the combustion appliance zone still drafts.
After correcting the source, we re-run the worst-case test along with combustion and draft readings, proving CO sits in spec and the flue draws without spilling, then log the before/after numbers.
Because standard UL-2034 alarms stay silent until 70 ppm, low-level (≈7-ppm) monitors go near appliances and sleeping areas to catch the chronic exposure those alarms miss.
Codes cited are the established national standards (NFPA, UL, IRC) that govern this service. The adopted code edition, permit, and inspection requirements vary by city —Texas Service verifies them with your local authority having jurisdiction on every job.
Read CO, O2, and stack temp on a combustion analyzer, and measure draft right at the hood.
Run a worst-case depressurization test, doors closed and exhaust going, to force any spillage into view.
Tune the burner, correct the draft, add combustion air, or resize an orphaned flue, whichever the finding calls for.
Re-take the readings and rerun the worst-case test, document before and after, and set low-level monitors or an interlock if you want them.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
A combustion analyzer reads CO, O2, and stack temp right at the appliance, so the numbers are measured rather than guessed.
Worst-case (BPI-style) depressurization test catches intermittent spillage
The fix is matched to what the finding shows, then re-checked against the same readings.
Low-level (7-ppm) monitor placement and spillage-interlock wiring available if you want the added protection.
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends a Level 1 inspection every year, with a sweep once buildup reaches 1/8" of creosote — for a wood fireplace you actually use, that's about once a heating season. The neighborly part: since we're already on the roof, the same crew checks your dryer vent and caps the visit with a quick whole-home safety look, so one appointment covers what would otherwise be three.
Yes — our inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable in the CSIA member directory at csia.org, and we have NFI specialists for fireplace work. The same trained crew handles your chimney, fireplace, dryer-vent and air-duct needs, so you're not juggling four different contractors for one house.
Yes — 24/7 response (subject to crew availability) for active leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. One call reaches one crew that can handle whatever the situation turns out to need, instead of bouncing you between specialists while the water's still coming in.
Always — a written quote before we lift a tool, with photos of what we found, so you see exactly what you're approving. If the same visit turns up something in the dryer vent or ducts, it goes on one itemized quote and one invoice rather than a string of separate trips.
The Whole-Home Care Plan is our annual maintenance plan at $19.99/month ($240/year): a Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Because one crew covers chimney, fireplace, dryer-vent and ducts, the plan keeps the whole house on a single schedule instead of a calendar full of separate service calls. Cancel anytime, no contract.
Last reviewed:
Other services in the Remediation & Remodel category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line